Description
100mm x 55mm x 8.1kg Galvanised IPE 100 Steel Beam
The 100mm x 55mm x 8.1kg Galvanised IPE 100 Steel Beam is an IPE 100 European parallel-flange I-section, hot-dip galvanised for improved corrosion resistance.
Its I-shaped profile provides strength and resistance to bending, making it suitable for structural supports, frames, lintels and general construction or fabrication work when correctly specified.
This product is available cut to your required length for convenient delivery and installation.
Technical Specifications
| Material | Structural steel |
|---|---|
| European section designation | IPE 100 |
| Section type | European parallel-flange I-section |
| Nominal depth | 100 mm |
| Nominal flange width | 55 mm |
| Nominal web thickness | 4.1 mm |
| Nominal flange thickness | 5.7 mm |
| Nominal root radius | 7 mm |
| Nominal mass | 8.1kg per metre |
| Nominal section area | Approximately 10.3 cm² |
| Material grade | Normally supplied as S275JR structural steel to BS EN 10025-2 |
| Grade confirmation | A particular grade is only guaranteed following written confirmation from KI Metals before ordering |
| Finish | Hot-dip galvanised zinc coating |
| Galvanising standard | BS EN ISO 1461:2022, where applicable to the supplied product |
| Galvanising process | Normally cut to length before hot-dip galvanising |
| Process hole | Approximately 8 mm where required for handling and suspension during galvanising |
| Cut-end protection | Some items may be cut after galvanising and protected with zinc-rich cold galvanising spray |
| Cutting service | Cut to your required length |
| Standard cutting tolerance | ±3 mm |
| Edge condition | Supplied as-cut and not deburred |
Key Features
- Recognised IPE 100 European beam profile
- Parallel-flange I-shaped structural section
- Nominal depth of 100 mm and flange width of 55 mm
- Nominal mass of 8.1kg per metre
- Hot-dip-galvanised for improved corrosion resistance
- Available cut to your required length
- Approximately 8 mm galvanising process hole where required
European IPE 100 Section
This product is an IPE 100 European parallel-flange I-section. Although it may sometimes be described generally as an RSJ, I-beam or steel beam, its recognised section designation is IPE 100. It should not be confused with a British Universal Beam.
The designation identifies a section with a nominal depth of 100 mm, a nominal flange width of 55 mm and a nominal mass of approximately 8.1kg per metre.
Structural Steel Grade Information
This IPE 100 beam is normally supplied as S275JR structural steel to BS EN 10025-2.
The grade information shown does not guarantee that S275JR or another particular grade will be supplied for an individual order.
If your project requires S275JR, another particular material grade, certification or traceability, please contact KI Metals before placing your order and obtain written confirmation from KI Metals.
Telephone conversations, verbal discussions, customer order notes, notes included with drawings and other instructions submitted with an order do not constitute confirmation of the material grade.
A particular grade, certification or traceability is only confirmed where KI Metals has provided written confirmation before the order is placed.
Galvanising Process and Cut-End Protection
Galvanised Steel Beams are normally cut to the required length before being sent for hot-dip galvanising.
Each pre-cut beam will usually include an approximately 8 mm process hole where required so that the material can be safely handled and suspended during the galvanising process. The position of the hole may vary according to the beam size, length and galvanising requirements. This is a normal production feature and is not a product defect.
In some cases, material may be galvanised in full lengths and cut afterwards. Where this method is used, the exposed cut ends are protected with a suitable zinc-rich cold galvanising spray.
If zinc-rich cold galvanising spray is not permitted for your project, or you require the cut ends to be hot-dip galvanised, please contact KI Metals before placing your order. We can review your cutting and galvanising requirements and confirm the most suitable production method.
Surface Condition
Hot-dip galvanising is an industrial protective process rather than a decorative finish. The surface may include variations in colour, brightness and texture, together with zinc spangle, drainage marks, minor runs, handling marks, areas of surface roughness or variations around edges and process holes.
These cosmetic variations are normal characteristics of hot-dip-galvanised steel and do not necessarily indicate a fault with the product or coating.
Corrosion Protection
The hot-dip-galvanised zinc coating provides improved resistance to atmospheric corrosion compared with untreated structural steel. The service life of the coating depends on the environment, exposure conditions, installation and maintenance.
Cutting, drilling, grinding or welding after delivery may expose the underlying steel. Affected areas should be protected with a suitable zinc-rich repair coating where continued corrosion resistance is required.
Typical Applications
- Structural openings and load-bearing supports
- Building frames and renovation projects
- Lintels, goalposts and support structures
- External steelwork
- Industrial fabrication and civil engineering
- Agricultural and commercial structures
- Platforms and supporting frameworks
Structural Design and Suitability
Beam selection must not be based on dimensions alone. The required section, material grade, loading capacity, span, bearing details, connections and installation method should be specified or approved by a suitably qualified structural engineer.
KI Metals supplies the material to the dimensions ordered but does not determine whether a particular beam is suitable for the intended load or application.
Cut to Your Required Length
Enter your required measurement in the Length box before adding the product to your basket. We will cut the beam to your specified length with a standard cutting tolerance of ±3 mm. The ordered quantity refers to the number of individual cut lengths required.
Products are supplied as-cut and are not deburred. Please contact KI Metals before ordering if your project requires a tighter tolerance, specific end preparation or additional processing.
Also Known As
- Galvanised steel beam
- Galvanised I-beam
- Galvanised I-section
- Galvanised RSJ
- Galvanised girder
- Galvanised steel lintel
Welding and Fabrication
Galvanised steel can be welded, drilled and fabricated, but suitable preparation and safety precautions must be followed.
Heating or welding galvanised steel can produce hazardous zinc oxide fumes. Suitable ventilation, local fume extraction, respiratory protection and appropriate personal protective equipment must be used.
The zinc coating should be removed from the immediate weld area before welding. After fabrication, affected areas should be cleaned and treated with an appropriate zinc-rich repair coating where continued corrosion protection is required.
Frequently Asked Questions
Is this a Universal Beam or an IPE beam?
This product is an IPE 100 European parallel-flange I-section. It may be described generally as a steel beam, I-beam or RSJ, but its recognised designation is IPE 100 rather than Universal Beam.
What do the measurements mean?
The section has a nominal depth of 100 mm and a nominal flange width of 55 mm. The 8.1kg figure represents the nominal mass per metre, not the total weight of the cut piece.
Is a particular steel grade guaranteed?
No. This section is normally supplied as S275JR structural steel to BS EN 10025-2. A particular grade is only guaranteed when KI Metals provides written confirmation before the order is placed. Telephone conversations, verbal discussions, order notes and notes supplied with drawings are not confirmation of material-grade requirements.
Why is there an 8 mm hole in the beam?
An approximately 8 mm process hole may be required so that the beam can be safely handled and suspended during hot-dip galvanising. This is a normal production feature and is not a product defect.
For some cutting requirements, material may instead be galvanised in full lengths and cut afterwards. Exposed cut ends are then protected with zinc-rich cold galvanising spray. If this repair method is not acceptable, please contact KI Metals before ordering.
Can this beam be used outdoors?
The hot-dip-galvanised coating provides improved protection for external applications. Expected service life depends on the environment, installation, exposure conditions and maintenance.
Can it be cut to my required length?
Yes. Enter your required length before adding the product to your basket. The standard cutting tolerance is ±3 mm.
Will every beam have the same galvanised appearance?
Not necessarily. Variations in colour, brightness, zinc spangle and surface texture are normal characteristics of hot-dip-galvanised steel.
Can I choose this beam based only on its dimensions?
No. A suitably qualified structural engineer should confirm the section, grade, loading capacity, span, connections, bearing details and installation requirements.
Safety Notice
This is a heavy structural steel product and may require suitable mechanical lifting equipment.
Cut ends and edges may be sharp and can retain burrs. Wear suitable gloves, safety footwear, eye protection and other appropriate personal protective equipment.
Ensure the beam is correctly supported and secured during storage, lifting, transportation and installation. Do not weld, grind or heat galvanised steel without suitable ventilation, fume extraction and respiratory protection.


























































Reviews
There are no reviews yet.